|  | Industrial Cables |  | |
|  | |||
 Industrial Cables
Industrial Cables
                      H00V-D
Application and Description
                        
                      H00V-D cables  are used for earthing of portable equipment and short circuiting. H00V-D cables perform a protective function in the live repair of high voltage power supply in railway systems, failing
                      current equipment, alternating current systems and in networks of transmission and distribution. Because
                      of that these are designated as safety cables. These earthing cables offer special characteristics with low
                      weights, high flexibility to a wide temperature range and the behavior in high temperature. The protective
      overall PVC jacket assure essential function for proper protection against mechanical and chemical stresses.
Standard and Approval
<HAR> EN61138, VDE-0283 Part-3, DIN 46438 & DIN 46440, CE low voltage directive 73/23/EEC & 93/68/
                      EEC., ROHS compliant
Cable Construction
Extra fine bare copper strands
                        Strands to DIN VDE 0295, BS 6360, IEC 60228 and HD 383
                        Overall bare copper wire braid (for ESUY type)
                        PVC transparent jacket TM2
                        High stress resistance
                        Spark Test 6, 4 & 2 AWG: 5000V
                        Spark Test 1 & 2/0 AWG: 6000V
      Spark Test 3/0 500 MCM: 8000V
Technical Characteristics
Working voltage: N/A earthing only
                        Test voltage: 2000 volts
                        Minimal bending radius: 12.0 x Ø
                        Temperature range: -5º C to +70º C
                        Flame retardant: IEC 60332.1
      Insulation resistance: 20 MΩ x km

Cable Parameter
H00V-D (ESEU type)| AWG | No. of Cores x Nominal Cross Sectional Area # x mm² | Nominal Overall Diameter mm | Nominal Copper Weight kg/Km | Nominal Weight kg/Km | 
| 6(4200/41) | 1 x 16 | 9.1 | 194 | 230 | 
| 4(3192/38) | 1 x 25 | 10.5 | 280 | 335 | 
| 2(4480/38) | 1 x 35 | 12.5 | 415 | 475 | 
| 1(6383/38) | 1 x 50 | 14.2 | 585 | 670 | 
| 2/0(8918/38) | 1 x 70 | 16.8 | 820 | 905 | 
| 3/0(12100/38) | 1 x 95 | 19.8 | 1090 | 1220 | 
| 4/0(15300/38) | 1 x 120 | 21.5 | 1360 | 1505 | 
| 300MCM(19152/38) | 1 x 150 | 24 | 1650 | 1940 | 
| 350MCM(23580/38) | 1 x 185 | 27.6 | 2150 | 2390 | 
| 500MCM(30600/38) | 1 x 240 | 31 | 2750 | 3090 | 
H00V-D (ESY type)
| AWG | No. of Cores x Nominal Cross Sectional Area # x mm² | Nominal Overall Diameter mm | Nominal Copper Weight kg/Km | Nominal Weight kg/Km | 
| 1 x 16 | 8.5 | 155 | 185 | |
| 4(798/32) | 1 x 25 | 10.0 | 240 | 270 | 
| 2(1120/32) | 1 x 35 | 12.5 | 336 | 390 | 
| 1(1617/32) | 1 x 50 | 14.0 | 480 | 575 | 
| 2/0(2254/32) | 1 x 70 | 17.2 | 672 | 810 | 
| 3/0(3087/32) | 1 x 95 | 19.5 | 912 | 1080 | 
| 4/0(3822/32) | 1 x 120 | 22.8 | 1152 | 1320 | 
| 300MCM(4802/32) | 1 x 150 | 25.4 | 1440 | 1680 |