|  | Industrial Cables |  | |
|  | |||
 Industrial Cables
Industrial Cables
                      H03V2V2-F/H03V2V2H2-F
Application and Description
                        
                      
                        H03V2V2-F/H03V2V2H2-F cables are suitable for domestic premises, kitchen, office for light service or light portable
                        apparatuses. With their special insulation and sheath compounds H03V2V2-F/H03V2V2H2-F cables are adapt for apparatus in
                        kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without
                        contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings
                        or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high
      temperature use, skin contact must be avoided.
Standard and Approval
<HAR>HD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295
                      CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1
Cable Construction
Bare copper fine wire conductor
                        Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
                        PVC core insulation T13 to VDE-0281 Part 1
                        Color coded to VDE-0293-308
      PVC outer jacket TM3
 
            
Technical Characteristics
Working voltage: 300/300 volts
                        Test voltage: 3000 volts
                        Flexing bending radius: 15 x Ø
                        Static bending radius: 4 x Ø
                        Flexing temperature: +5º C to +90º C
                        Static temperature: -40º C to +90º C
                        Short circuit temperature: +160º C
                        Flame retardant: IEC 60332.1
      Insulation resistance: 20 MΩ x km
 
         
Cable Parameter
| AWG | No. of Cores x Nominal Cross Sectional Area # x mm² | Nominal Thickness of Insulation mm  | Nominal Thickness of Sheath mm  | Nominal Overall Diameter mm  | Nominal Copper Weight kg/Km | Nominal Weight kg/Km | 
| H03V2V2-F | ||||||
| 20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 5 | 9.6 | 38 | 
| 20(16/32) | 3 x 0.50 | 0.5 | 0.6 | 5.4 | 14.4 | 45 | 
| 20(16/32) | 4 x 0.50 | 0.5 | 0.6 | 5.8 | 19.2 | 55 | 
| 18(24/32) | 2 x 0.75 | 0.5 | 0.6 | 5.5 | 14.4 | 46 | 
| 18(24/32) | 3 x 0.75 | 0.5 | 0.6 | 6 | 21.6 | 59 | 
| 18(24/32) | 4 x 0.75 | 0.5 | 0.6 | 6.5 | 28.8 | 72 | 
| H03V2V2H2-F | ||||||
| 20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 3.2 x 5.2 | 9.7 | 32 | 
| 18(24/32) | 2 x 0.75 | 0.5 | 0.6 | 3.4 x 5.6 | 14.4 | 35 |