|  | Industrial Cables |  | |
|  | |||
 Industrial Cables
Industrial Cables
                      H05RN-F/H05RNH2-F
Application and Description
                        
                      H05RN-F/H05RNH2-F cables are flexible, mainly recommended for use in electrical equipment under low stress in dry, damp
                        and wet areas in indoor or outdoor environments. Commonly used for connection of electrical appliances
                        when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is
                        minimal physical damage. Also suitable for fixed installation in furniture, decorative coverings, wall partitions
                        and pre-fabricated building parts. Max operating voltage in single or three phase system is Uo/U 318/550
                        volts. In a direct current system max operating voltage is Uo/U 413/825 volts. They are ozone resistant, oil &
      fat resistant
Standard and Approval
<HAR> HD22.4 S3, VDE-0282 Part-4, CEI 20-19 p.4,CE low voltage directive 73/23/EEC & 93/68/EEC.,
                      IEC 60245-4, ROHS compliant
Cable Construction
Fine bare copper strands
                        Strands to VDE-0295 Class-5, IEC 60228 Class-5
                        Rubber core insulation EI4 to VDE-0282 Part-1
                        Color code VDE-0293-308
                        Green-yellow grounding, 3 conductors and above
      Polychloroprene rubber (neoprene) jacket EM2
 
             
Technical Characteristics
Working voltage: 300/500 volts
                        Test voltage: 2000 volts
                        Flexing bending radius: 7.5 x Ø
                        Fixed bending radius: 4.0 x Ø
                        Temperature Range: -30º C to +60º C
                        Short circuit temperature: +200 º C
                        Flame retardant: IEC 60332.1
      Insulation resistance: 20 MΩ x km
 
           
Cable Parameter
| AWG | No. of Cores x Nominal Cross Sectional Area # x mm² | Nominal Thickness of Insulation mm  | Nominal Thickness of Sheath mm  | Nominal Overall Diameter mm min-max | Nominal Copper Weight kg/Km | Nominal Weight kg/Km | 
| H05RN-F | ||||||
| 18(24/32) | 2 x 0.75 | 0.6 | 0.8 | 5.7 7.4 | 14.4 | 80 | 
| 18(24/32) | 3 x 0.75 | 0.6 | 0.9 | 6.2 8.1 | 21.6 | 95 | 
| 18(24/32) | 4 x 0.75 | 0.6 | 0.9 | 6.8 8.8 | 30 | 105 | 
| 17(32/32) | 2 x 1 | 0.6 | 0.9 | 6.1 8.0 | 19 | 95 | 
| 17(32/32) | 3 x 1 | 0.6 | 0.9 | 6.5 8.5 | 29 | 115 | 
| 17(32/32) | 4 x 1 | 0.6 | 0.9 | 7.1 – 9.2 | 38 | 142 | 
| 16(30/30) | 3 x 1.5 | 0.8 | 1.0 | 8.6 11.0 | 29 | 105 | 
| 16(30/30) | 4 x 1.5 | 0.8 | 1.1 | 9.5 12.2 | 39 | 129 | 
| 16(30/30) | 5 x 1.5 | 0.8 | 1.1 | 10.5 13.5 | 48 | 153 | 
| H05RNH2-F | ||||||
| 16(30/30) | 2 x 1.5 | 0.6 | 0.8 | 5.25±0.15x13.50±0.30 | 14.4 | 80 | 
| 14(50/30) | 2 x 2.5 | 0.6 | 0.9 | 5.25±0.15x13.50±0.30 | 21.6 | 95 |